Power Conditioner |
|
Maximum Output Current, Total |
15 Amps @ 120 Volts AC |
|
Maximum Output Current, Per Outlet/Bank |
15 Amps @ 120 Volts AC (subject to a maximum total output current of 15 Amps for all outlets combined) |
|
Filtration |
40 dB @ 100 kHz, 50 dB @ 300 kHz, with 50 Ohm load |
|
Surge Protection Modes |
L-G, L-N, N-G |
|
Surge Protection Shutoff |
Shuts off rear outlets if surge protection is compromised |
|
Energy Dissipation |
2000 Joules per Mode |
|
Clamping Voltage |
370 Volts |
|
Clamping Time |
1 ns |
|
Wiring Fault Detection |
Shuts off rear outlets if a wiring fault is detected at the input [1] |
|
Under-Voltage Cutoff |
Shuts off rear outlets if input drops below 93 Volts |
|
Over-Voltage Cutoff |
Shuts off rear outlets if input exceeds 135 Volts |
|
Turn-On Delay |
SWITCHED ON 1: 0 seconds;
SWITCHED ON 2: 0 seconds;
DELAYED ON 1: 1 second;
DELAYED ON 2: 2 seconds |
Power |
|
Line Power |
15 Amps @ 120 Volts AC, 60 Hz |
|
Power Consumption |
~10 Watts typical, 30 Watts maximum (not including load) |
Connectors |
|
120V~ 15A 60Hz |
(1) Attached 9.8 ft (3 m) grounded AC power cord with NEMA 5-15P plug;
Line power input |
|
SWITCHED ON 1 |
(2) NEMA 5-15R AC power outlets;
Switched 120 Volt AC power outlet bank;
Turn-On Delay: 0 seconds |
|
SWITCHED ON 2 |
(2) NEMA 5-15R AC power outlets;
Switched 120 Volt AC power outlet bank;
Turn-On Delay: 0 seconds |
|
DELAYED ON 1 |
(2) NEMA 5-15R AC power outlets;
Switched 120 Volt AC power outlet bank;
Turn-On Delay: 1 second |
|
DELAYED ON 2 |
(2) NEMA 5-15R AC power outlets;
Switched 120 Volt AC power outlet bank;
Turn-On Delay: 2 seconds |
|
PROTECTION |
(1) 2-pin 3.5 mm detachable terminal block;
Normally open, isolated relay;
Rated 1 Amp, 30 Volts AC/DC;
Provides a dry contact closure if surge protection is compromised |
|
G |
(1) 6-32 screw, chassis ground lug |
|
ALWAYS ON (front) |
(1) NEMA 5-15R AC power outlet;
Unswitched 120 Volt AC power outlet |
Controls & Indicators |
|
PWR |
(1) Bi-color green/amber LED, indicates line power is present and the power switch is on (green) or off (amber) |
|
FAULT |
(1) Red LED, indicates any of the following fault conditions: surge protection is compromised, line and neutral are reversed, or no ground is detected [1] |
|
PROTECT |
(1) Green LED, indicates surge protection is fully functional |
|
SHUTDOWN |
(1) Amber LED, indicates power to the rear outlets is shut off due to an over-voltage, under-voltage, line input miswire, missing ground, or compromised surge protection fault condition |
|
Power Switch |
(1) Rocker switch, "On" position initiates turn-on delay sequence to the rear panel outlets, "Off" position turns all rear outlets off immediately |
|
THERMAL BREAKER (rear) |
Disrupts power to all outlets in case of an overload condition, press to reset after overload condition is resolved |
Environmental |
|
Temperature |
32° to 113° F (0° to 45° C) |
|
Humidity |
10% to 90% RH (non-condensing) |
|
Heat Dissipation |
34 BTU/hr typical;
102 BTU/hr maximum |
Construction |
|
Chassis |
Steel, black finish |
|
Front Panel |
Extruded aluminum, black finish, polycarbonate label overlay |
|
Mounting |
1 RU 19-inch rack-mountable (rack ears included) |
Dimensions |
|
Height |
1.73 in (44 mm) without feet |
|
Width |
17.32 in (440 mm);
19.00 in (483 mm) with rack ears |
|
Depth |
10.56 in (269 mm) |
Weight |
|
8.2 lb (3.8 kg) |
Compliance |
|
UL 1449 Type 3 Listed
In the CSEA region, available in Macau & Hong Kong only. |